Taian TP03 Error 8066: Circuit error

Taian TP03 programmable controller · taken from the manufacturer’s manual, pages cited

Error code8066

The 8066 code indicates a circuit error with possible codes 0000, 6603, or 6604. The manual's first action is: “No abnormality”

Model
Taian TP03
Display shows
Circuit error (8066)
Type
Error code
Source
Manual p. 143

What 8066 means

Circuit error p. 143

Common causes

What to do

  1. No abnormality p. 143
  2. MPS used continuously more than 8 times p. 143
  3. MPS MRD MPP relationship error p. 143
  4. STL used continuously more than 16 times p. 143
  5. Call to non‑existent label p. 143
  6. I, IRET, SRET present in main program p. 143
  7. STL, RET, MC, MCR, SMCS, SMCR, JCS, JCR present between FOR and NEXT p. 143
  8. CALL nesting exceeds 16 levels p. 143
  9. FOR/NEXT mismatch p. 143
  10. JCS, JCR relationship incorrect p. 143
  11. STL, RET relationship incorrect p. 143
  12. MC, MCR relationship incorrect p. 143
  13. SMCS, SMCR relationship incorrect p. 143
  14. I, IRET relationship incorrect p. 143
  15. MC, MCR, SMCS, SMCR, SRET present in STL_RET p. 143
  16. FOR/NEXT nesting exceeds 16 levels p. 143
  17. No END p. 143
  18. Other error. p. 143

Before you service the product, read the safety instructions in the manual p. 101.

If 8066 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Taian service.

This page summarises what the manufacturer’s manual says about 8066; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Taian. Found a mistake? Report an error.