Sidadianzi JPSD3000 Error OU: Main circuit overvoltage

Solar inverter · taken from the manufacturer’s manual, pages cited

Alarm codeOU

The OU code indicates main circuit overvoltage, which occurs when regenerative energy during motor deceleration raises the main circuit DC voltage above the safe limit. The manual's first action is: “Keep the supply within the specified limits.”

Model
Sidadianzi JPSD3000
Display shows
Main circuit overvoltage (OU)
Type
Alarm code
Source
Manual p. 52

What OU means

Main circuit overvoltage p. 53

Common causes

  • Regenerative energy during motor deceleration raises the main circuit DC voltage above the safe limit, causing the inverter to alarm and stop output. p. 53
  • a. Check whether the supply voltage is too high. p. 53
  • b. It is likely that the load inertia (GD²) is too large. p. 53

What to do

  1. Keep the supply within the specified limits. p. 53
  2. Increase the deceleration time to suit the load inertia. p. 53

Before you service the product, read the safety instructions in the manual p. 57.

If OU is still not resolved

  • contact service or dealer p. 11
    “如果匹配电机与变频器额定值不符合,务必调整保护值”
  • contact service or dealer p. 16
    “用户不可再对变频进行耐压实验”

This page summarises what the manufacturer’s manual says about OU; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sidadianzi. Found a mistake? Report an error.