Shenyang Hongda Textile Machinery FA306A Error H1.2: When the cylinder is full, the PLC length‑control system sends a full‑cylinder signal that stops the machine (full‑cylinder automatic stop)

Textile stripper machine · taken from the manufacturer’s manual, pages cited

Alarm codeH1.2

H1.2 indicates the cylinder is full, which triggers the machine to stop automatically. The manual's first action is: “When the full‑cylinder automatic stop occurs, the green lamp H1.2 on tower light H1 and the indicator on the touch‑screen alarm screen illuminate simultaneously. Five seconds after the cylinder change begins, the full‑cylinder signal is automatically cleared, the green lamp H1.2 turns off, and H4 is extinguished.”

Model
Shenyang Hongda Textile Machinery FA306A
Display shows
H1.2
Type
Alarm code
Source
Manual p. 5

What H1.2 means

When the cylinder is full, the PLC length‑control system sends a full‑cylinder signal that stops the machine (full‑cylinder automatic stop) p. 5

Common causes

  • When the cylinder is full, the PLC length‑control system sends a full‑cylinder signal that stops the machine (full‑cylinder automatic stop) p. 5

What to do

  1. When the full‑cylinder automatic stop occurs, the green lamp H1.2 on tower light H1 and the indicator on the touch‑screen alarm screen illuminate simultaneously. Five seconds after the cylinder change begins, the full‑cylinder signal is automatically cleared, the green lamp H1.2 turns off, and H4 is extinguished. p. 5

Before you service the product, read the safety instructions in the manual p. 7.

If H1.2 is still not resolved

  • 找出原因,排除故障,按合已脱扣的自动开关 p. 6
    “找出原因,排除故障,按合已脱扣的自动开关”
  • 按启动按钮可使机器重新投入运行 p. 6
    “按启动按钮可使机器重新投入运行”

This page summarises what the manufacturer’s manual says about H1.2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Shenyang Hongda Textile Machinery. Found a mistake? Report an error.