Schneider Electric ATV 21 Error EEP1: E'PROM fault 1 (write error)

Schneider Electric ATV 21 Frequency Transformer · taken from the manufacturer’s manual, pages cited

Error codeEEP1

This code indicates E'PROM fault 1 (write error). The manual's first action is: “Turn off the inverter, then turn it on again. If the error does not clear, call service.”

Model
Schneider Electric ATV 21
Display shows
E'PROM fault 1 (write error) (EEP1)
Type
Error code
Source
Manual p. 189

What EEP1 means

E'PROM fault 1 (write error) p. 235

Common causes

  • A stop command was entered from the operator panel or a remote input device during automatic or remote operation. p. 235

What to do

  1. Turn off the inverter, then turn it on again. If the error does not clear, call service. p. 235

Before you service the product, read the safety instructions in the manual p. 8.

If EEP1 is still not resolved

  • Contact local sales agent for parts replacement. p. 7
    “如要更换零件,请致电当地的销售代理处”
  • Perform daily equipment inspection. p. 7
    “应每天对设备进行检查”

This page summarises what the manufacturer’s manual says about EEP1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.