Fault codeECF
Break in encoder's mechanical coupling The manual's first action is: “Check the encoder's mechanical coupling”
- Model
- Schneider Electric Altivar 71W
- Display shows
- [ENCODER COUPLING] (ECF)
- Type
- Fault code
- Source
- Manual p. 70
What ECF means
[ENCODER COUPLING] p. 70
Common causes
- Break in encoder's mechanical coupling p. 70
What to do
- Check the encoder's mechanical coupling p. 70
Before you service the product, read the safety instructions in the manual p. 41.
If ECF is still not resolved
- contact Schneider Electric service p. 42 “Failure to follow these instructions will result in death, serious physical injury or equipment damage.”
This page summarises what the manufacturer’s manual says about ECF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.