RYS MHT260a Error AL OF: Overflow, deviation excessive

Motor amplifier · taken from the manufacturer’s manual, pages cited

Alarm codeAL OF

The deviation between command and feedback positions has exceeded the set value for basic parameter 54, indicating excessive positional error. The manual's first action is: “The initial set value of basic para. 54 is 10000 (× 100) [pulse]. If the difference between the current command position and current feedback position exceeds 1000000 [pulse], an alarm is detected. Under normal operating conditions, the deviation quantity increases in proportion to the motor speed. If an alarm is detected when rotating the motor by turning on the [RUN], the motor power wiring phases U, V, W may not be connected to the corresponding terminals (U, V, W) of the amplifier. The set value of basic para. 54 need not be decreased. The deviation quantity can be reduced by setting the feed forward gain of basic para. 40 to near 1.000.”

Model
RYS MHT260a
Display shows
Overflow, deviation excessive (AL OF)
Type
Alarm code
Source
Manual p. 247

What AL OF means

Overflow, deviation excessive p. 252

Common causes

  • Overflow, deviation excessive p. 252
  • Deviation quantity (difference between the current command position and current feedback position) exceeded the set value of basic para. 54. p. 252

What to do

  1. The initial set value of basic para. 54 is 10000 (× 100) [pulse]. If the difference between the current command position and current feedback position exceeds 1000000 [pulse], an alarm is detected. Under normal operating conditions, the deviation quantity increases in proportion to the motor speed. If an alarm is detected when rotating the motor by turning on the [RUN], the motor power wiring phases U, V, W may not be connected to the corresponding terminals (U, V, W) of the amplifier. The set value of basic para. 54 need not be decreased. The deviation quantity can be reduced by setting the feed forward gain of basic para. 40 to near 1.000. p. 252

Before you service the product, read the safety instructions in the manual p. 3.

If AL OF is still not resolved

  • Contact Fuji for special systems or applications such as atomic-energy control, aerospace use, medical use, and traffic control. p. 4
    “Customers, who want to use the products introduced in this manual for special systems or devices such as for atomic-energy control, aerospace use, medical use, and traffic control, are requested to consult the Fuji.”