Error codes from p. 166

CodeDisplay messageWhat it meansPage
041 Out of toner. 缺粉。 p. 166
001 No record paper in the paper tray. Record paper has not entered the machine. 纸盒中无记录纸。记录纸未进入机器。 p. 170
007 Record paper has not fully exited the fax machine. 记录纸未完全从传真机中出纸。 p. 170
012 Received data exceeds the maximum paper size in the feeding direction. 接收的数据超出进纸方向的最大纸张尺寸。 p. 170
021 Even after the heating circuit is 'ON', the fusing temperature does not rise. The fusing temperature exceeds the controllable temperature limit. The cooling fan inside the machine is not running. 即便在加热电路“开启”后定影温度也未上升。定影温度超出可控温度的上限。机器中的冷却风扇不转。 p. 170
030 Document jam. 文件卡纸。 p. 170
031 Document paper is too long or jammed. Document length exceeds 2 meters. 文件纸张太长或卡纸。文件长度超出 2 米。 p. 170
043 Insufficient toner. 墨粉不足。 p. 170
045 Drum unit not installed. 硒鼓未安装。 p. 170
051 DC motor problem. 直流电机出现问题。 p. 170
054 Polygon motor does not stabilize within the specified time after being turned 'ON'. 多棱镜电机在“开启”后指定时间内未稳定下来。 p. 170
060 Printer cover open. 打印机盖板打开。 p. 170
061 ADF door open. ADF 门打开。 p. 170
068 Rear cover open. 后盖板打开。 p. 170
091 Cooling fuser unit. 冷却定影单元。 p. 170
092 Drum unit has reached its service life. 硒鼓达到使用寿命。 p. 170
093 Operating the machine in a low-temperature environment where print quality cannot be guaranteed. 在无法保证打印质量的低温环境下使用机器。 p. 170
400 During the initial handshake, the receiving station did not respond or a communication error occurred. 在初始握手过程中,接收站未响应或者发生通信故障。 p. 170
401 Remote station requires a receive password to accept the document. Remote station does not have a secure mailbox. Remote station requires the sender's ID number (fax telephone number). 远端站点需要接收密码来接收文件。远端站点不具备机密邮箱。远端站点需要发送方的 ID 号码(传真电话号码)。 p. 170
402 Communication error occurred during the initial handshake. 在初始握手过程中,发生通信故障。 p. 171
403 Remote side has no query function. 远端方无查询功能。 p. 171
404/406 Communication error occurred during the initial handshake. 在初始握手过程中,发生通信故障。 p. 171
406 Send password mismatch. Receive password mismatch. Document received from an unauthorized station in selective receive mode. 发送密码不匹配。 接收密码不匹配。 在选择性接收模式下从未经授权的站点 接收到文件。 p. 171
407 The receiving station did not acknowledge the previously sent page. 接收站并未对之前发送的页面进行确认。 p. 171
408/409 The remote party reports that the previously sent page is difficult to read. 远端方确认之前发送的页面难以辨认。 p. 171
410 Communication was interrupted due to a problem on the sending side. 通信因发送方原因而中断。 p. 171
411 Query password mismatch. 查询密码不匹配。 p. 171
412 The sending side did not transmit any data. 发送方未发送数据。 p. 171
414 Query password mismatch. 查询密码不匹配。 p. 171
415 Error occurred while sending the query. 查询发送出错。 p. 171
416/417 Too many errors were detected in the received data. 接收到的数据错误太多。 p. 171
420/421 The machine entered receive mode but did not receive a command from the sender. 机器进入接收模式,但未从发送方接收到命令。 p. 171
422/427 Interface incompatibility. 接口不兼容。 p. 171
434 Communication failure occurred during reception. 接收时发生通信故障。 p. 171
494 Communication failure occurred during reception. 接收时发生通信故障。 p. 171
495 Telephone line interruption. 电话线中断。 p. 171
504 Query rejected because no query data were provided. 由于无查询数据,查询遭到拒绝。 p. 171
505 Query rejected due to an incorrect password. 由于密码错误,查询遭到拒绝。 p. 171
550 Telephone line interruption. 电话线中断。 p. 171
554 Communication failure occurred during reception. 接收时发生通信故障。 p. 171
580 Attempted subaddress transmission to a machine that does not support subaddressing. 向不具有子地址功能的机器进行子地址发送。 p. 171
623 No document loaded in the ADF. ADF 中没有装入文件。 p. 171
630 Redial failed because the line was busy. 重新拨号因占线而未成功。 p. 171
631 The stop key was pressed during dialing. 拨号期间按下了停止键。 p. 171
634 Redial failed because no answer was received from the called site or the number was dialed incorrectly. 重新拨号因未从呼叫站点得到应答或拨错号码而未成功。 p. 172
638 Power failure occurred during communication. 在通信期间发生电源故障。 p. 172
731 When a computer fax request was received, the dialer buffer for manual dialing was full (10 stations). 接收到电脑传真请求时,用于手动拨号的拨号机缓冲区已满(10 个站点)。 p. 172
741 Dialing failed due to missing phone number. Occurs when using the program key to delete a scheduled entry or when shortening the dialed number. 由于电话号码缺失,拨号失败。使用程序键删除预约单触键/缩位拨号号码时出现。 p. 172
815 Mailbox is full. 邮箱已满。 p. 172
870 Memory overflow occurs when storing a file in memory for transmission. 将文件存入内存进行发送时,发生内存溢出。 p. 172

Fault codes from p. 170

CodeDisplay messageWhat it meansPage
090 High-voltage unit fault. 高压单元故障。 p. 170
094 Drum unit fault. 硒鼓故障。 p. 170
722 Failed to obtain network parameters (e.g., IP address, subnet mask, default gateway IP address, etc.) from the DHCP server. 未能从 DHCP 服务器获取网络参数(如 IP 地址、子网掩码、默认网关 IP 地址等)。 p. 172