Analog torque command input to terminal CCWTL (pin 16 of X5) exceeds the specified value (±10 V or -10 V). The manual's first action is: “Check the wiring of connector X5.”
- Model
- Panasonic Minas A4
- Display shows
- CCWTL command overvoltage (65)
- Type
- Error code
- Source
- Manual p. 66
What 65 means
CCWTL command overvoltage p. 66
Common causes
- Analog torque command input to terminal CCWTL (pin 16 of X5) exceeds the specified value (±10 V or -10 V). This protection function only operates when CCWTL is present. Moreover, it can work more precisely if the following conditions are met. 1) Torque control mode: Pr02 = 5; or Pr02 = 2 or 4, and Pr5B = 1. 2) Position / speed / full closed‑loop control mode: Pr03 = 0. p. 66
What to do
- Check the wiring of connector X5. p. 66
- The maximum voltage that can be input to CCWTL is ±10 V. p. 66
- The maximum voltage that can be input to CWTL is ±10 V. p. 66
Before you service the product, read the safety instructions in the manual p. 72.
If 65 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.
This page summarises what the manufacturer’s manual says about 65; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.