Panasonic MINAS A-series Error 97: Full close selection error

Servo motor driver · taken from the manufacturer’s manual, pages cited

Error code97

Full close selection error means when an 11-wire encoder is used, Pr02 (control mode selection) is set to 7, 8 or 9 ("full-close" control). The manual's first action is: “Set the value of Pr02 to 0, 1, 2, 3, 4 or 5.”

Model
Panasonic MINAS A-series
Display shows
Full close selection error (97)
Type
Error code
Source
Manual p. 70

What 97 means

Full close selection error p. 70

Common causes

  • When an 11-wire encoder is used, Pr02 (control mode selection) is set to 7, 8 or 9 ("full-close" control). p. 70

What to do

  1. Set the value of Pr02 to 0, 1, 2, 3, 4 or 5. p. 70

Before you service the product, read the safety instructions in the manual p. 4.

If 97 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 97; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.