Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
Discharge temperature error occurs when discharge temperature exceeds 23°F (110°C) twice in 24 hours. The manual's first action is: “-Check if 3-way valve is open. -Check EEV, strainer. (Ref. Service Tip #001-HFI Disc…
The 4-way valve error code indicates the compressor stops when indoor heat exchanger temp minus room temp exceeds 20°F (cooling) or falls below -20°F (heating). The manual lists no action for this code.
Heat sink thermistor error indicates the heat sink temperature thermistor is open or shorted. The manual's first action is: “-Check for erroneous connection or removed connector.”
Outdoor thermistor error detected when outdoor temperature thermistor is open or short-circuited. The manual's first action is: “-Check connection of connector, loose, erroneous connection.”
Heat Exchanger (Pipe) Thermistor Error – When heat exchanger temperature thermistor open or short-circuit is detected at power up or while running the compressor. The manual's first action is: “-Check connection of co…
Compressor thermistor error detected when the compressor temperature sensor is open or short-circuited while powered on or running. The manual's first action is: “-Check for erroneous connection or removed connector.”
Discharge thermistor error detected when the thermistor is open or short-circuited during power-up or compressor operation. The manual's first action is: “-Check connection of connector, loose, erroneous connection.”
IPM error / Trip terminal I error indicates abnormal current at the IPM due to blocked heat radiation. The manual's first action is: “-Check connections of outdoor unit electrical components.”
Active filter / PFC Circuit error code 64 indicates abnormal DC voltage levels or repeated power interruptions. The manual's first action is: “-Check external cause at the indoor or outdoor (voltage drop or noise).”
Inverter error indicates a problem with the inverter's transistor PCB. The manual's first action is: “Check connection of molex plugs on inverter PCB for loose connections.”
Outdoor unit main PCB error The manual's first action is: “Check external cause; voltage drop, poor ground connection.”
The system has detected a problem with the drain pump. The manual's first action is: “Check connector of (CN9) / wire.”
Indoor unit fan motor error code 51 indicates the fan's actual frequency is below one-third of its target for more than 56 seconds. The manual's first action is: “Check rotation of fan.”
Human sensor error code 44 indicates a fault in the human sensor or its connection. The manual's first action is: “Check erroneous connection.”
Indoor heat exchanger thermistor error detected. The manual's first action is: “Check thermistor resistance value.”