Temperature Fault 2 means one or more temperature inputs set in P3.9.6.5 are above the fault limit, requiring sensor or wiring check. The manual's first action is: “Find the cause of the temperature rise.”
Temperature Fault 2 means one or more temperature inputs set in P3.9.6.5 are above the fault limit, requiring sensor or wiring check. The manual's first action is: “Find the cause of the temperature rise.”
Temperature Fault 1 means one or more temperature inputs are above the fault limit, requiring sensor or wiring check. The manual's first action is: “Find the cause of the temperature rise.”
Temperature Fault 1 means one or more temperature inputs are above the alarm limit, requiring sensor or wiring check. The manual's first action is: “Find the cause of the temperature rise.”
ID 1409 - Input Pressure Supervision means the input pressure signal is below the fault limit set in P3.13.9.8. The manual lists no action for this code.
ID 1109 - Input Pressure Supervision means the input pressure signal is below the alarm limit set in P3.13.9.7. The manual's first action is: “Check the process.”
ID 1105 - Feedback Supervision Fault (ExtPID) means the feedback value is outside supervision limits or delay settings for ExtPID. The manual's first action is: “Check the process.”
ID 1101 - Feedback Supervision Fault (PID 1) means the feedback value is outside supervision limits or delay settings for PID 1. The manual's first action is: “Check the process.”
ID 1100 - Soft Fill Timeout means the PID controller did not achieve the process value within its time limit, possibly due to a broken pipe. The manual's first action is: “Check the process.”
ID 1078 - Identification Ongoing means the drive is running identification for the motor. The manual's first action is: “You can stop the identification run at any time by removing the start command. When the identifi…
ID 1077 - > 5 Connections occurs when more than five active fieldbus or PC tool connections are present, limiting to five at a time. The manual's first action is: “Leave 5 active connections. Remove the other connecti…
Start Prevented occurs to block start command during first power-up to prevent accidental rotation. The manual lists no action for this code.
Stator Winding: Current Warning S1 occurs when current unbalance exceeds detection limits, indicating early motor fault requiring stator winding check. The manual's first action is: “Check motor stator windings.”
BaselineRun Failed occurs when there was a failure during baseline run, requiring checking baseline run settings. The manual's first action is: “Do a check of the parameters in the baseline run settings.”
Fieldbus Mapping Error occurs if ID numbers for Fieldbus Process Data Out are invalid or types undefined, requiring checking parameters in Fieldbus Data menu. The manual's first action is: “Check the parameters in the…