Lenovo M7020/7030/7120/7130N M3020/3120/3220 Error BE: Scan start edge detection error (not used)

Lenovo M7020/7030/7120/7130N M3020/3120/3220 · taken from the manufacturer’s manual, pages cited

Error codeBE

Scan start edge detection error (not used) occurs when the CIS is defective, the CIS flat cable is damaged or not connected, or the motherboard fails. The manual's first action is: “Replace scanner cover (scanner unit)”

Model
Lenovo M7020/7030/7120/7130N M3020/3120/3220
Display shows
Scan start edge detection error (not used) (BE)
Type
Error code
Source
Manual p. 192

What BE means

Scan start edge detection error (not used) p. 192

Common causes

  • CIS defect p. 192
  • CIS flat cable damaged or not connected p. 192
  • Motherboard failure p. 192
  • White level reference film on scanner unit is dirty p. 192

What to do

  1. Replace scanner cover (scanner unit) p. 192
  2. Reconnect cable correctly, replace scanner cover (scanner unit) p. 192
  3. Replace motherboard. p. 192

Before you service the product, read the safety instructions in the manual p. 10.

If BE is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Lenovo service.

This page summarises what the manufacturer’s manual says about BE; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Lenovo. Found a mistake? Report an error.