Scan start edge detection error (not used) occurs when the CIS is defective, the CIS flat cable is damaged or not connected, or the motherboard fails. The manual's first action is: “Replace scanner cover (scanner unit)”
- Model
- Lenovo M7020/7030/7120/7130N M3020/3120/3220
- Display shows
- Scan start edge detection error (not used) (BE)
- Type
- Error code
- Source
- Manual p. 192
What BE means
Scan start edge detection error (not used) p. 192
Common causes
- CIS defect p. 192
- CIS flat cable damaged or not connected p. 192
- Motherboard failure p. 192
- White level reference film on scanner unit is dirty p. 192
What to do
- Replace scanner cover (scanner unit) p. 192
- Reconnect cable correctly, replace scanner cover (scanner unit) p. 192
- Replace motherboard. p. 192
Before you service the product, read the safety instructions in the manual p. 10.
If BE is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Lenovo service.