The 51h code indicates a S.M.A.R.T. FUNCTION SET command error when the required key is not loaded, the subcommand value is invalid or unsupported, or a non-SMART ENABLE OPERATIONS subcommand is received while S.M.A.R.T. is disabled. The manual's first action is: “04h”
- Model
- IBM DPTA-3xxxxx
- Display shows
- 51h
- Type
- Error code
- Source
- Manual p. 180
What 51h means
A S.M.A.R.T. FUNCTION SET command was received by the device without the required key being loaded into the Cylinder High and Cylinder Low registers. p. 180
Common causes
- A S.M.A.R.T. FUNCTION SET command was received by the device without the required key being loaded into the Cylinder High and Cylinder Low registers. p. 180
- A S.M.A.R.T. FUNCTION SET command was received by the device with a subcommand value in the Features Register that is either invalid or not supported by this device. p. 180
- A S.M.A.R.T. FUNCTION SET command subcommand other than SMART ENABLE OPERATIONS was received by the device while the device was in a "S.M.A.R.T. disabled" state. p. 180
- The device is unable to read its Attribute Values or Attribute Thresholds data structure. p. 180
- The device is unable to write to its Attribute Values data structure. p. 180
What to do
If 51h is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact IBM service.
This page summarises what the manufacturer’s manual says about 51h; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with IBM. Found a mistake? Report an error.