Haier JSQ26-TFM(R) Error E6: Dry fire protection

Gas water heater · taken from the manufacturer’s manual, pages cited

Error codeE6

Dry fire protection means the unit detected no water in the tank during heating. The manual's first action is: “Inspect the heating element and thermostat”

Model
Haier JSQ26-TFM(R)
Display shows
Dry fire protection (E6)
Type
Error code
Source
Manual p. 2

What E6 means

Dry fire protection p. 2

Common causes

  • Dry fire protection p. 2

What to do

  1. Inspect the heating element and thermostat p. 2

Before you service the product, read the safety instructions in the manual p. 1.

If E6 is still not resolved

  • 联系海尔售后服务中心 p. 2
    “若问题仍不能解决,或遇到其他故障,请联系海尔售后服务中心或请有资质的专业人员进行修理。”
  • 请有资质的专业人员进行修理 p. 2
    “若问题仍不能解决,或遇到其他故障,请联系海尔售后服务中心或请有资质的专业人员进行修理。”

This page summarises what the manufacturer’s manual says about E6; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Haier. Found a mistake? Report an error.