Goldair 3PH Error HP2: When the unit is operating in any mode and the above fault (open circuit) occurs

Goldair 3PH Integrated Control System · taken from the manufacturer’s manual, pages cited

Fault codeHP2

Code HP2 indicates an open circuit fault occurs during any operating mode. The manual's first action is: “After a 2‑second delay the fault is displayed and the unit that experienced the fault is stopped. For a dual‑unit system: if both compressors fault, both compressors stop running and the fault is displayed; a manual restart is required, but the fan continues to run for 8 seconds before stopping. If only one compressor faults, that compressor stops running and a fault alarm is generated, but the compressor‑running indicator remains on, indicating that the other compressor is still operating. After the fault is cleared, the alarm disappears; the faulty compressor must be manually reset before it can be started. This is defined as code 31 (HP1) and 71 (HP2) on the main board.”

Model
Goldair 3PH
Display shows
HP2
Type
Fault code
Source
Manual p. 37

What HP2 means

When the unit is operating in any mode and the above fault (open circuit) occurs p. 37

Common causes

  • When the unit is operating in any mode and the above fault (open circuit) occurs p. 37

What to do

  1. After a 2‑second delay the fault is displayed and the unit that experienced the fault is stopped. For a dual‑unit system: if both compressors fault, both compressors stop running and the fault is displayed; a manual restart is required, but the fan continues to run for 8 seconds before stopping. If only one compressor faults, that compressor stops running and a fault alarm is generated, but the compressor‑running indicator remains on, indicating that the other compressor is still operating. After the fault is cleared, the alarm disappears; the faulty compressor must be manually reset before it can be started. This is defined as code 31 (HP1) and 71 (HP2) on the main board. p. 37

Before you service the product, read the safety instructions in the manual p. 3.

If HP2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Goldair service.

This page summarises what the manufacturer’s manual says about HP2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Goldair. Found a mistake? Report an error.