Fujioh FH-IC6020 Error E2: Ceramic plate temperature sensor failure--short circuit

Fujioh FH-IC6020 · taken from the manufacturer’s manual, pages cited

Error codeE2

Ceramic plate temperature sensor failure--short circuit The manual's first action is: “Check the connection or replace the ceramic plate temperature sensor.”

Model
Fujioh FH-IC6020
Display shows
Ceramic plate temperature sensor failure--short circuit (E2)
Type
Error code
Source
Manual p. 18

What E2 means

Ceramic plate temperature sensor failure--short circuit p. 18

Common causes

  • Ceramic plate temperature sensor failure--short circuit. p. 18

What to do

  1. Check the connection or replace the ceramic plate temperature sensor. p. 18

If E2 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fujioh service.

This page summarises what the manufacturer’s manual says about E2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fujioh. Found a mistake? Report an error.