Input Phase Missing Protection occurs when an input phase is missing. The manual's first action is: “Stop inverter. This function prevents damage to capacitors and transformers in the inverter due to power phase missing or phase imbalance. That is, in case of light load or near DC current instantaneously, phase missing may not be detected.”
- Model
- Fuji Electric FRENIC‑Multi
- Display shows
- Input Phase Missing Protection (1in)
- Type
- Error code
- Source
- Manual p. 177
What 1in means
Input Phase Missing Protection p. 177
Common causes
- Detected input phase missing p. 177
What to do
- Stop inverter. This function prevents damage to capacitors and transformers in the inverter due to power phase missing or phase imbalance. That is, in case of light load or near DC current instantaneously, phase missing may not be detected. p. 177
Before you service the product, read the safety instructions in the manual p. 3.
If 1in is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fuji Electric service.
This page summarises what the manufacturer’s manual says about 1in; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fuji Electric. Found a mistake? Report an error.