Fagor Servo Drive System Error 801: Encoder not detected (with motor feedback).

Fagor Servo Drive System · taken from the manufacturer’s manual, pages cited

Error code801

Code 801 means the encoder is not detected with motor feedback due to the feedback not being connected or not being in excellent condition. The manual's first action is: “Ensure the GP2 value matches the installed feedback type. For example, when the motor feedback is a resolver, the GP2 parameter value should be "0" (sine‑wave encoder). Contact Fagor.”

Model
Fagor Servo Drive System
Display shows
Encoder not detected (with motor feedback). (801)
Type
Error code
Source
Manual p. 552

What 801 means

Encoder not detected (with motor feedback). p. 552

Common causes

  • Ensure the feedback is connected and in excellent condition. p. 552

What to do

  1. Ensure the GP2 value matches the installed feedback type. For example, when the motor feedback is a resolver, the GP2 parameter value should be "0" (sine‑wave encoder). Contact Fagor. p. 552

Before you service the product, read the safety instructions in the manual p. 444.

If 801 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.

This page summarises what the manufacturer’s manual says about 801; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.