Delta VFD007C43A Error oSL: Overslip Error

Delta VFD007C43A · taken from the manufacturer’s manual, pages cited

Error codeoSL

Overslip Error means slip exceeds the set point of parameter 05-26 and the duration exceeds the time set in parameter 05-27. The manual's first action is: “Check whether the motor parameters are correct; if the load is too large, reduce the load. Verify the set values of parameters 05-26 and 05-27.”

Model
Delta VFD007C43A
Display shows
Overslip Error (oSL)
Type
Error code
Source
Manual p. 376

What oSL means

Overslip Error p. 376

Common causes

  • When slip exceeds the set point of parameter 05-26 and the duration exceeds the time set in parameter 05-27, an oSL occurs. p. 376

What to do

  1. Check whether the motor parameters are correct; if the load is too large, reduce the load. Verify the set values of parameters 05-26 and 05-27. p. 376

Before you service the product, read the safety instructions in the manual p. 366.

If oSL is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about oSL; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.