Delta VFD-VL Error 7: Over torque (OT1)

Delta VFD-VL · taken from the manufacturer’s manual, pages cited

Error code7

Over torque (OT1) means the drive has detected an over‑torque event. The manual's first action is: “This contact will close. Parameter 06-06 sets the over‑torque detection level; parameter 06-07 sets the over‑torque detection time. (See 06-05~06-07)”

Model
Delta VFD-VL
Display shows
Over torque (OT1) (7)
Type
Error code
Source
Manual p. 92

What 7 means

Over torque (OT1) p. 92

Common causes

  • When the drive detects an over‑torque event p. 92

What to do

  1. This contact will close. Parameter 06-06 sets the over‑torque detection level; parameter 06-07 sets the over‑torque detection time. (See 06-05~06-07) p. 92

Before you service the product, read the safety instructions in the manual p. 4.

If 7 is still not resolved

  • 若有任何疑慮的地方請連絡本公司各地的代理商洽詢 p. 4
    “若有任何疑慮的地方請連絡本公司各地的代理商洽詢”
  • 我們的專業人員會樂於為您服務 p. 4
    “我們的專業人員會樂於為您服務”

This page summarises what the manufacturer’s manual says about 7; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.