Warning codeW08
There is a string fault due to incorrect DC connector polarity or failed string current monitoring. The manual's first action is: “1. Check the polarity of PV connection 2. Restart DC switch and AC breaker 3. Contact customer service for technical support”
- Model
- Delta M70A_263
- Display shows
- String fault (W08)
- Type
- Warning code
- Source
- Manual p. 76
What W08 means
String fault p. 76
Common causes
- 1. Polarity of DC connectors is incorrect 2. String current monitoring function is fail p. 76
What to do
- 1. Check the polarity of PV connection 2. Restart DC switch and AC breaker 3. Contact customer service for technical support p. 76