Error codeB301
The calculation result of the variable lead thread is less than 0. The manual's first action is: “Check the G code command and modify the program.”
- Model
- Delta IA-CNC_Milling
- Display shows
- Threading pitch error (B301)
- Type
- Error code
- Source
- Manual p. 428
What B301 means
Threading pitch error p. 428
Common causes
- The calculation result of the variable lead thread is less than 0. p. 428
What to do
- Check the G code command and modify the program. p. 428
Before you service the product, read the safety instructions in the manual p. 3.
If B301 is still not resolved
- Contact service / dealer p. 3 “Refer to the pin assignment when wiring.”
This page summarises what the manufacturer’s manual says about B301; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.