Error codes from p. 82

CodeDisplay messageWhat it meansPage
1 Low 10 V voltage 10V 电压低 p. 82
3 No motor 无电机 p. 82
4 Main power phase loss 主电源缺相 p. 82
5 High DC circuit voltage 直流回路电压高 p. 82
6 Low DC circuit voltage 直流回路电压低 p. 82
7 DC overvoltage 直流过压 p. 82
8 DC circuit undervoltage 直流回路欠压 p. 82
9 Inverter overload 逆变器过载 p. 82
10 Motor ETR temperature high 电机 ETR 温度高 p. 82
11 Motor thermistor temperature high 电机热电阻温度高 p. 82
12 Torque limit 转矩极限 p. 82
13 Overcurrent 过电流 p. 82
15 Incompatible hardware 不兼容硬件 p. 82
16 Short circuit 短路 p. 82
17 Control word timeout 控制字超时 p. 82
23 Internal fan 内部风扇 p. 82
24 External fan 外部风扇 p. 82
25 Brake resistor short circuit 制动电阻器短路 p. 82
26 Brake resistor power limit 制动电阻功率极限 p. 82
27 Brake chopper short circuit 制动斩波器短路 p. 82
28 Brake check 制动检查 p. 82
29 Power card temperature 功率卡温度 p. 82
30 Motor U phase loss 电动机 U 相缺相 p. 82
31 Motor V phase missing 电动机 V 相缺相 p. 82
32 Motor W phase missing 电动机 W 相缺相 p. 82
40 T27 overload T27 过载 p. 82
41 T29 overload T29 过载 p. 82
42 X30/6 overload X30/6 过载 p. 82
48 1.8 V power supply low limit 1.8 V 电源下限 p. 82
49 Speed limit 速度极限 p. 82
50 AMA adjustment failure AMA 调整失败 p. 82
51 AMA check Unom and Inom AMA 检查 Unom 和 Inom p. 82
52 AMA low limit AMA 下限 p. 82
53 AMA motor too large AMA 电动机过大 p. 82
54 AMA motor too small AMA 电动机过小 p. 82
55 AMA parameter out of range AMA 参数超出范围 p. 82
56 AMA interrupted by user AMA 被用户中断 p. 82
57 AMA timeout AMA 超时 p. 82
58 AMA internal error AMA 内部错误 p. 82
59 Current limit 电流极限 p. 82
61 Tracking error 跟踪错误 p. 82
62 Output frequency limit 输出频率极限 p. 82
63 Mechanical brake too low 机械制动过低 p. 82
64 Voltage limit 电压极限 p. 82
65 Control card temperature 控制卡温度 p. 82
66 Heatsink temperature low 散热片温度低 p. 82
67 Optional module configuration changed 选件配置已更改 p. 82
68 Safety stop 安全停止 p. 82
70 FC configuration non‑compliant FC 配置不合规 p. 82
71 PTC 1 safety stop PTC 1 安全停止 p. 82
90 Encoder lost 编码器丢失 p. 82
91 A154 setting error A154 设置错误 p. 82
517 Write command timed out 写入命令处于超时状态 p. 85
1281 DSP flash memory timeout 数字信号处理器的闪存超时 p. 85
1282 Power card microprocessor software version mismatch 功率卡微处理器的软件版本不匹配 p. 85
1283 Power card EEPROM data version mismatch 功率卡 EEPROM 数据版本不匹配 p. 85
1284 Unable to read DSP software version 无法读取数字信号处理器的软件版本 p. 85
1299 Optional module software version in slot A is outdated 插槽 A 中的选件软件版本过旧 p. 85
1300 Optional module software version in slot B is outdated 插槽 B 中的选件软件版本过旧 p. 85
1311 Optional module software version in slot C0 is outdated 插槽 C0 中的选件软件版本过旧 p. 85
1312 Optional module software version in slot C1 is outdated 插槽 C1 中的选件软件版本过旧 p. 85
1315 Optional module software version in slot A is unsupported (not allowed) 插槽 A 中的选件软件版本不受支持(不允许) p. 85
1316 Optional module software version in slot B is unsupported (not allowed) 插槽 B 中的选件软件版本不受支持(不允许) p. 85
1317 Optional module software version in slot C0 is unsupported (not allowed) 插槽 C0 中的选件软件版本不受支持(不允许) p. 85
1318 The optional module software version in slot C1 is not supported (not permitted). 插槽 C1 中的选件软件版本不受支持(不允许) p. 85
1536 An exception occurred in application‑oriented control and was logged. Debug information has been written to the LCP. 面向应用的控制中出现异常并被记录下来。调试信息已写入 LCP 中 p. 85
1792 Control data from the DSP watchdog was not transmitted correctly. DSP 守护机的控制数据未正确传输。 p. 85
2049 Power card data has been restarted. 功率卡数据已重新启动 p. 85
2315 Power card unit is missing a software version. 功率卡单元缺少软件版本 p. 85
2816 Stack overflow in the control board module. 控制板模块的堆栈溢出 p. 85
2820 LCP stack overflow. LCP 堆栈溢出 p. 85
2821 Serial port overflow. 串行端口溢出 p. 85
2822 USB port overflow. USB 端口溢出 p. 85
3072-5122 Parameter value exceeded its limits. Initialization was performed. The parameter number that caused this alarm is obtained by subtracting 3072 from the error code. For extended error code 9238: 3238‑3072 = 166, indicating an out‑of‑limit condition. 参数值超出了其极限。执行初始化,导致此报警的参数号:用错误代码减去 3072。扩展错误代码 9238: 3238-3072 = 166,表明超出了极限 p. 85
5123 Optional module in slot A: hardware is incompatible with the control board hardware. 插槽 A 中的选件:硬件与控制板硬件不兼容 p. 85
5124 Optional module in slot B: hardware is incompatible with the control board hardware. 插槽 B 中的选件:硬件与控制板硬件不兼容 p. 85
5125 Optional module in slot C0: hardware is incompatible with the control board hardware. 插槽 C0 中的选件:硬件与控制板硬件不兼容 p. 85
5126 Optional module in slot C1: hardware is incompatible with the control board hardware. 插槽 C1 中的选件:硬件与控制板硬件不兼容 p. 85
5376-6231 Insufficient memory. 内存不足 p. 85
T27 Check the load connected to terminal 27, or remove any short‑circuit connection. Check parameters 5-00 and 5-01. 检查与端子 27 相连的负载,或拆除短路连接。检查参数 5-00 和 5-01. p. 85
T29 Check the load connected to terminal 29, or remove any short‑circuit connection. Check parameters 5-00 and 5-02. 检查与端子 29 相连的负载,或拆除短路连接。检查参数 5-00 和 5-02. p. 85

Fault codes from p. 82

CodeDisplay messageWhat it meansPage
2 Open circuit fault 断线故障 p. 82
14 Ground fault 接地故障 p. 82
33 Charging fault 充电故障 p. 82
34 Bus communication fault 总线通讯故障 p. 82
36 Main power fault 主电源故障 p. 82
38 Internal fault 内部故障 p. 82
47 24 V power supply fault 24 V 电源故障 p. 82
72 Dangerous fault 危险故障 p. 82
80 Inverter initialized to default values 变频器初始化为默认值 p. 82
518 EEPROM fault EEPROM 发生故障 p. 85
519 Barcode data in EEPROM missing or invalid, 1024‑1279, CAN messages cannot be sent. (1027 indicates a possible hardware fault) EEPROM 中的条形码数据丢失或无效,1024 - 1279, CAN 报文无法发送。(1027 表明可能发生了硬件故障) p. 85

Warning codes from p. 85

CodeDisplay messageWhat it meansPage
PTC 1 Safety stop was activated from MCB 112 PTC thermistor (motor overheating). Normal operation can be restored if MCB 112 again applies a 24 V DC supply to terminal 37 (when motor temperature has reached an acceptable level and the digital input from MCB 112 is not activated). 已从 MCB 112 PTC 热敏电阻激活安全停止(电动机过热)。如果 MCB 112 再次在端子 37 上施加 24 V 直流电源(当电动机温度达到可接受的水平并且来自 MCB 112 的数字输入未被激活时),则可以恢复正常运行。 p. 85