Danaher Motion S200 Error 19: Position error too large

Danaher Motion S200 · taken from the manufacturer’s manual, pages cited

Fault code19

Position error too large indicates step size overflow means GearOut/GearIn is too large, position error overflow means the error has exceeded ±128 revs, or the motor is stalling or the commanded speed is higher than the motor can achieve at the present bus voltage. The manual lists no action for this code.

Model
Danaher Motion S200
Display shows
Position error too large (19)
Type
Fault code
Source
Manual p. 98

What 19 means

Position error too large p. 98

Common causes

  • Check ExtFaults: ExtFaults = Step size over flow means GearOut/GearIn is too large. p. 98
  • ExtFaults = Position error over flow means that the following error, = PosErr, has exceeded ±128 revs. p. 98
  • Check if the motor is stalling or if the commanded speed is higher than the motor can achieve at the present bus voltage. p. 98

If 19 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Danaher Motion service.

This page summarises what the manufacturer’s manual says about 19; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Danaher Motion. Found a mistake? Report an error.