Control Techniques Mentor II Error PhS: Phase sequence

Mentor II DC Drive · taken from the manufacturer’s manual, pages cited

Fault codePhS

Phase sequence means the connections to E1 and E3 are not the same phases as connected to L1 and L3. Investigate and correct. The manual lists no action for this code.

Model
Control Techniques Mentor II
Display shows
Phase sequence (PhS)
Type
Fault code
Source
Manual p. 101

What PhS means

Phase sequence p. 101

Common causes

  • Connections to E1 and E3 are not the same phases as are connected to L1 and L3. Investigate and correct p. 101

If PhS is still not resolved

  • disconnect by an approved electrical isolation device p. 6
    “supply must be disconnected by an approved electrical isolation device”
  • DISCONNECT and ISOLATED before any work is done p. 19
    “drive has been connected to the main AC supply system it must be DISCONNECTED and ISOLATED before any work is done”

This page summarises what the manufacturer’s manual says about PhS; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Control Techniques. Found a mistake? Report an error.