Fault codeFbr
Feedback reversal indicates the polarity of the feedback tacho or encoder is incorrect. The manual lists no action for this code.
- Model
- Control Techniques Mentor II
- Display shows
- Feedback reversal (Fbr)
- Type
- Fault code
- Source
- Manual p. 101
What Fbr means
Feedback reversal p. 101
Common causes
- The polarity of the feedback tacho or encoder polarity is incorrect. This trip does not operate on 1Q drives p. 101
If Fbr is still not resolved
- disconnect by an approved electrical isolation device p. 6 “supply must be disconnected by an approved electrical isolation device”
- DISCONNECT and ISOLATED before any work is done p. 19 “drive has been connected to the main AC supply system it must be DISCONNECTED and ISOLATED before any work is done”
This page summarises what the manufacturer’s manual says about Fbr; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Control Techniques. Found a mistake? Report an error.