Beijing-Fanuc 0i-MA Error 749: S-spindle LSI error

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Fault code749

S-spindle LSI error means serial spindle communication error due to fiber optic cable connection fault, main CPU board fault, or spindle amplifier printed circuit board fault. The manual's first action is: “1) Fiber optic cable connection fault, cable not connected, or cable cut. 2) Main CPU board fault. 3) Spindle amplifier printed circuit board fault. If this alarm occurs and cannot be cleared by powering on the CNC or resetting the CNC, turn off the CNC power and spindle power, then restart.”

Model
Beijing-Fanuc 0i-MA
Display shows
S-spindle LSI error (749)
Type
Fault code
Source
Manual p. 737

What 749 means

S-spindle LSI error p. 737

Common causes

  • Serial spindle communication error. Possible causes include: p. 737

What to do

  1. 1) Fiber optic cable connection fault, cable not connected, or cable cut. 2) Main CPU board fault. 3) Spindle amplifier printed circuit board fault. If this alarm occurs and cannot be cleared by powering on the CNC or resetting the CNC, turn off the CNC power and spindle power, then restart. p. 737

Before you service the product, read the safety instructions in the manual p. 18.

If 749 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 749; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.