Beijing-Fanuc 0i-MA Error 5157: Parameter 0

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code5157

Parameter 0 means maximum cutting feed parameter is set to 0 or acceleration/deceleration parameters before interpolation are set to 0. The manual's first action is: “Set the parameters correctly.”

Model
Beijing-Fanuc 0i-MA
Display shows
Parameter 0 (5157)
Type
Error code
Source
Manual p. 732

What 5157 means

Parameter 0 p. 732

Common causes

  • Maximum cutting feed parameter is set to 0 (parameters No.1422, 1433). p. 732
  • Acceleration/deceleration parameters before interpolation are set to 0 (parameters No.1770, 1771). p. 732

What to do

  1. Set the parameters correctly. p. 732

Before you service the product, read the safety instructions in the manual p. 18.

If 5157 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 5157; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.