Beijing-Fanuc 0i-MA Error 142: Illegal scaling ratio

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code142

Illegal scaling ratio means a scaling factor outside the range 1 to 999,999 was commanded. The manual's first action is: “Correct the scaling ratio setting (G51 Pp. or parameters 5411, 5421).”

Model
Beijing-Fanuc 0i-MA
Display shows
Illegal scaling ratio (142)
Type
Error code
Source
Manual p. 729

What 142 means

Illegal scaling ratio p. 729

Common causes

  • A scaling factor outside the range 1 to 999,999 was commanded. p. 729

What to do

  1. Correct the scaling ratio setting (G51 Pp. or parameters 5411, 5421). p. 729

Before you service the product, read the safety instructions in the manual p. 18.

If 142 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 142; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.