Reference point return not completed means the start point for reference point return is too close to the reference point or the speed is too low to perform the return. The manual's first action is: “Place the reference point far enough from the start point or specify a sufficiently fast speed for the return.”
- Model
- Beijing-Fanuc 0i-MA
- Display shows
- Reference point return not completed (090)
- Type
- Error code
- Source
- Manual p. 727
What 090 means
Reference point return not completed p. 727
Common causes
- The start point for reference point return is too close to the reference point or the speed is too low to perform the return. p. 727
What to do
- Place the reference point far enough from the start point or specify a sufficiently fast speed for the return. p. 727
Before you service the product, read the safety instructions in the manual p. 18.
If 090 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.
This page summarises what the manufacturer’s manual says about 090; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.