STOP MOTION OR DWELL means the stop pulse allocation flag is set due to external reset or reset/reverse signals. The manual's first action is: “Modify the program.”
- Model
- Beijing-Fanuc 0i-MA
- Display shows
- STOP MOTION OR DWELL (025)
- Type
- Alarm code
- Source
- Manual p. 515
What 025 means
STOP MOTION OR DWELL p. 725
Common causes
- Stop pulse allocation flag. Set in the following situations. p. 725
- (1) External reset signal is on. p. 725
- (2) Reset/reverse signal is on. p. 725
- (3) Emergency stop. p. 725
- (4) Feed pause. p. 725
- (5) Reset key on the MDI panel is engaged. p. 725
- (6) Manual mode (JOG/HANDLE/INC). p. 725
- (7) When other alarms occur. p. 725
- (Alarm that has not been set.) p. 725
- During circular interpolation, F1 was commanded with F0. p. 725
What to do
- Modify the program. p. 725
Before you service the product, read the safety instructions in the manual p. 18.
If 025 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.
This page summarises what the manufacturer’s manual says about 025; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.