Analog Devices ADM1075 Error 6: HOTSWAP_OFF

Hot swap controller · taken from the manufacturer’s manual, pages cited

Fault code6

HOTSWAP_OFF means the hot swap gate drive output is disabled and the GATE pin is pulled down, which can be due to an overcurrent fault that causes the ADM1075 to latch off or an undervoltage condition. The manual lists no action for this code.

Model
Analog Devices ADM1075
Display shows
HOTSWAP_OFF (6)
Type
Fault code
Source
Manual p. 40

What 6 means

HOTSWAP_OFF p. 40

Common causes

  • The hot swap gate drive output is disabled, and the GATE pin is pulled down. This can be due to, for example, an overcurrent fault that causes the ADM1075 to latch off, an undervoltage condition on the UV pin, or the use of the OPERATION command to turn the output off. p. 40

If 6 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Analog Devices service.

This page summarises what the manufacturer’s manual says about 6; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Analog Devices. Found a mistake? Report an error.