ABB ACS150 Error F0035: OUTP WIRING (programmable fault function, parameter 3023 WIRING FAULT)

ABB ACS150 · taken from the manufacturer’s manual, pages cited

Fault codeF0035

F0035 means incorrect input power and motor cable connection, where the input power cable is connected to the drive motor connection, or the fault may be erroneously declared if the drive is faulty or the input power is delta ground. The manual's first action is: “Check input power connections.”

Model
ABB ACS150
Display shows
F0035
Type
Fault code
Source
Manual p. 131

What F0035 means

OUTP WIRING (programmable fault function, parameter 3023 WIRING FAULT) p. 131

Common causes

  • Incorrect input power and motor cable connection (that is input power cable is connected to drive motor connection). Fault can be erroneously declared if drive is faulty or input power is delta grounded system and motor cable capacitance is large. p. 131

What to do

  1. Check input power connections. p. 131

Before you service the product, read the safety instructions in the manual p. 149.

If F0035 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about F0035; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.