ABB ACS 400 Error 17: UNDERLOAD

ABB ACS 400 low voltage AC drive · taken from the manufacturer’s manual, pages cited

Error code17

Code 17 is UNDERLOAD, meaning motor load is too low. The manual's first action is: “Check for a problem in the driven equipment. Refer to parameters 3013 – 3015”

Model
ABB ACS 400
Display shows
UNDERLOAD (17)
Type
Error code
Source
Manual p. 157

What 17 means

UNDERLOAD p. 157

Common causes

  • Motor load is too low. p. 157

What to do

  1. Check for a problem in the driven equipment. Refer to parameters 3013 – 3015 p. 157

Before you service the product, read the safety instructions in the manual p. 97.

If 17 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact ABB service.

This page summarises what the manufacturer’s manual says about 17; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.