CB OVERTEMP indicates the drive control board has overheated due to ambient temperature, fan failure, or obstructions. The manual's first action is: “Check for and correct: • Excessive ambient temperatures • Fan failure. • Obstructions in the air flow.”

Model
ABB ACH550
Display shows
CB OVERTEMP (37)
Type
Error code
Source
Manual p. 27

What 37 means

CB OVERTEMP p. 27

Common causes

  • Drive control board overheated. p. 27

What to do

  1. Check for and correct: • Excessive ambient temperatures • Fan failure. • Obstructions in the air flow. p. 27

Before you service the product, read the safety instructions in the manual p. 2.

If 37 is still not resolved

  • contact the factory or your local Authorized Service Center for repair or replacement. p. 2
    “Never attempt to repair a malfunctioning ACH550; contact the factory or your local Authorized Service Center for repair or replacement.”