Philips Lumileds Understanding LED Performance
This article describes tools contained in LED datasheets that show how an LED will perform under real operating conditions. It uses a single-LED desk lamp example that compares high-performance power LEDs from four suppliers identified as MFR 1-4.
The article discusses flux normalisation, temperature derating, and lumen maintenance. Under the example conditions, the MFR 3 part cannot be used, while the MFR 4 LED produces at least 133 lumens when new and at least 70% of peak output after 50,000 hours; the MFR 2 part would need 407 mA to meet the same lifetime goal.
Covers: LED Lamp · Flux normalisation graph · Temperature derating graph · Lumen maintenance · Simple Comparisons
Latest Philips Lumileds manuals
Philips Lumileds Understanding LED Performance
Other 3 pages · 776 KB · ENThis Philips Lumileds article explains how to use LED datasheet tools to compare power LEDs under real operating conditions.
Questions answered in Philips Lumileds manuals
Why does the article compare the LEDs at 700 mA instead of 350 mA?
Driving the LEDs at 350 mA would not maximise light output for the design.
Which LED cannot be used under the example thermal conditions?
The MFR 3 part cannot be used because its junction temperature reaches 141°C, 16°C above its maximum rated value.