Simanfeng DXW-2A Electric Gastric Lavage Apparatus Instructions for Use
This document is the instructions for use of the Simanfeng DXW-2A electric gastric lavage apparatus (电动洗胃机), published by Shanghai Baojia Medical Device Co., Ltd. The machine is intended for use in medical units for emergency lavage in oral poisoning and food poisoning cases, and for pre-operative gastric lavage. It consists of an air pump, control circuit with software, a reversing device, gastric fluid and medication containers, and solenoid valves.
The manual describes the device's contraindications, safety warnings, working principle with a pressure feedback control system, front and rear panel controls, performance specifications, tubing installation and commissioning, the lavage working process, cleaning and disinfection, maintenance, EMC information, troubleshooting, waste disposal, operating and storage conditions, after-sales service and accessories. It also covers the oral and nasal intubation lavage modes and the fluid balance function. This manual is written in Chinese.
Covers: 概述 (Overview) · 安全警告 (Safety Warnings) · 特征和工作原理 (Features and Working Principle) · 开箱检查 (Unpacking Inspection) · 外观结构 (Appearance and Structure) · 性能指标 (Performance Specifications)
Latest 斯曼峰 manuals
Simanfeng DXW-2A Electric Gastric Lavage Apparatus Instructions for Use
User Manual 11 pages · 1 MB · ZHChinese instructions for use for the Simanfeng DXW-2A electric gastric lavage apparatus, covering operation, safety warnings, specifications, cleaning and…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in 斯曼峰 manuals
Which patients should not undergo gastric lavage with the DXW-2A?
Contraindicated patients include those who swallowed corrosive substances such as strong acids or alkalis, patients with upper GI ulcers or cancer, patients with intubation contraindications such as esophageal obstruction or varices, comatose patients, patients at risk of bleeding or gastric perforation, and infants or young children.
From: Simanfeng DXW-2A Electric Gastric Lavage Apparatus Instructions for Use
How does the fluid balance key work?
When fluid intake exceeds fluid output, pressing the fluid balance key reduces the intake volume by about 150–300 ml per cycle; pressing it 2–3 times before the end of lavage helps clear residual fluid from the stomach.
From: Simanfeng DXW-2A Electric Gastric Lavage Apparatus Instructions for Use