Key facts
- Manuals
- 1
- Languages
- ZH
- Last added
- 2023-11-11
Featured Nicronode manuals

Nicronode MD9207 Temperature Difference Automatic Controller User Manual
This manual describes the MD9207 temperature difference automatic controller from Beijing Micronode Technology Co., Ltd. (Nicronode). The instrument is a microcontroller-based measuring and control device that uses temperature and temperature difference to drive relay outputs and an analog output, and can be programmed with ten time periods, each running a different type of control. It measures three temperature points (temperature 0, 1 and 2); temperature 0 controls relay 0, while the difference between temperature 1 and temperature 2 controls relay 1 and an analog output. Models with the C suffix add RS485 communication for data transfer to a host computer.
The manual covers model naming, hardware specifications, panel layout and rear-panel wiring diagrams for both the relay-output and OC-gate-output versions, the three operating states (setting, working and non-working), basic and secondary parameter setting, restoring factory defaults, descriptions of the heating and temperature-difference control processes, and an explanation of hysteresis (回差) control. This manual is written in Chinese.
Covers: Model naming (型号命名) · Hardware specifications (硬件指标) · Function introduction (功能介绍) · Rear panel wiring diagrams (后面板接线图) · Operating states (工作状态) · Basic operations (基本操作)
Latest Nicronode manuals
Nicronode MD9207 Temperature Difference Automatic Controller User Manual
User Manual 30 pages · 789 KB · ZHUser manual for the Nicronode MD9207 temperature difference automatic controller, covering wiring, parameter setting, operation and RS485 communication.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Nicronode manuals
How do I reset the accumulated working time of the MD9207?
In the working state, press the Stop key for 4 to 6 seconds until the accumulated working time window shows 000.0, then release; the current work stops and all control outputs are turned off.
From: Nicronode MD9207 Temperature Difference Automatic Controller User Manual
What are the factory default run parameters?
Each time period defaults to a temperature 0 setting of 38°C, a time of 12 hours and a temperature difference of 1.5°C; secondary parameters default to HE1 0.5, HE2 0.5, HE3 1.0 and EE/0E1/0E2/0E3 all 0.
From: Nicronode MD9207 Temperature Difference Automatic Controller User Manual