Featured East & West manuals

East & West AF7500 Dual-Channel Hydride-Atomic Fluorescence Spectrometer Notes on Use
This document is a set of practical usage notes for the AF7500 dual-channel hydride generation atomic fluorescence spectrometer developed by Beijing East & West Analytical Instruments (北京市东西分析仪器有限公司). Written by Li Weimin of the Beijing East & West Electronics Technology Research Institute, it describes the instrument's main features, including low detection limits for 11 elements, dual optical paths for simultaneous two-element determination, a membrane gas-liquid separation system, and computer-controlled operation via the AF7500 workstation.
The main body gives operating advice for new users: using the instrument under the required environmental conditions (stable power supply, controlled humidity, exhaust ventilation), adjusting instrument state before measurement (lamp alignment, lamp current, photomultiplier negative high voltage, carrier and shielding gas flows), correctly preparing working solutions (acidity, sodium/potassium borohydride, valence adjustment), preventing contamination of trace-level samples, and notes on calibration and result validity (RSD ≤ 3, r ≥ 0.998). This manual is written in Chinese.
Covers: Instrument main features · Operating environment requirements · Adjusting instrument state before measurement · Lamp current selection · Negative high voltage selection · Carrier and shielding gas adjustment
Latest East & West manuals
East & West AF7500 Dual-Channel Hydride-Atomic Fluorescence Spectrometer Notes on Use
Application Note 7 pages · 45 KB · ZHUsage notes for the East & West AF7500 dual-channel hydride generation atomic fluorescence spectrometer, covering setup, lamp current, reagents and…
Which document do I need?
Application Note
How to use the product for one specific task, with worked examples.
Questions answered in East & West manuals
Can sodium borohydride replace potassium borohydride?
Yes, they can generally replace each other, but to keep the borohydride amount equal the sodium borohydride amount should be multiplied by a factor of 0.7 (sodium borohydride amount = 0.7 × potassium borohydride amount).
From: East & West AF7500 Dual-Channel Hydride-Atomic Fluorescence Spectrometer Notes on Use
Why is an exhaust device required?
The elements determined by hydride generation-atomic fluorescence, such as arsenic, mercury and lead, are toxic, and their gases escaping from the flame are harmful to the human body, so an exhaust device must be installed.
From: East & West AF7500 Dual-Channel Hydride-Atomic Fluorescence Spectrometer Notes on Use