Questions answered in Valent BioSciences manuals

Which mosquito larvae are used for Bti bioassays?

Bti bioassays use actively feeding L4 larvae of Aedes aegypti, with results expressed as ITU/mg relative to reference strain AM65-52 material.

From: Valent BioSciences Bacterial Larvicide Bioassay Standard Operating Procedure (SOP)

Which mosquito larvae are used for Bacillus sphaericus bioassays?

Bs bioassays use early L3 third instar larvae of Culex quinquefasciatus, with results expressed as Bs ITU/mg relative to reference strain ABTS-1743 material.