West of England Marine Diesel Engine Lubrication Loss Prevention Bulletin
This is a West of England (West P&I) Loss Prevention Bulletin on lubricating marine diesel engines. It notes that several entered vessels suffered main engine damage after using heavily contaminated lubricating oil, and explains why modern, more highly rated marine diesel engines are more easily damaged when operation, maintenance and lubrication are not carried out correctly.
The bulletin sets out the basic requirements for lubricating oil - viscosity limits, water content and insoluble solids, total base number (TBN) and flash point - then describes mechanical filters, centrifugal filters and centrifugal separators/purifiers, onboard and laboratory testing of oil samples, contaminant analysis methods, engine room watchkeeping, and how to top up and change lubricating oil. This manual is written in Chinese.
Covers: Lubrication of moving parts · Viscosity limits · Water content and insoluble solids · Total Base Number (TBN) · Flash point · Mechanical filters
Latest West of England manuals
West of England Marine Diesel Engine Lubrication Loss Prevention Bulletin
Other 4 pages · 539 KB · ZHLoss prevention bulletin from West of England on marine diesel engine lubrication: contamination, filters and separators, oil testing and oil changes.
Questions answered in West of England manuals
How often should water content and viscosity be tested on board?
Weekly, with the results recorded in the planned maintenance system.
From: West of England Marine Diesel Engine Lubrication Loss Prevention Bulletin
What does a flash point below the manufacturer's range indicate?
It may indicate the presence of light hydrocarbons, which can mean the oil has been contaminated by diesel.
From: West of England Marine Diesel Engine Lubrication Loss Prevention Bulletin