Key facts
- Manuals
- 1
- Languages
- ZH
- Last added
- 2026-11-07
Featured HZK manuals

HZK HSM6E Series Electronic Molded Case Circuit Breaker User Manual
The HZK HSM6E series electronic molded case circuit breakers are designed for AC 50 Hz systems with rated insulation voltage 1000 V, rated operational voltage up to 690 V, and rated currents from 32 A to 1600 A. They provide overload long-time delay, short-circuit short-time delay, short-circuit instantaneous, and ground-fault protection with adjustable current and time settings, plus a magnetic instantaneous backup trip. The breakers comply with IEC 60947-2 and GB/T 14048.2 standards and are suitable for altitudes up to 2000 m, ambient temperatures -5 °C to +40 °C, pollution degree 3, and installation category III.
The manual details installation requirements including busbar/cable cross-sections, tightening torques, safety clearances, altitude and temperature derating factors, and outline/drilling dimensions for front, rear, plug-in, and draw-out connections for each frame size (100, 250, 400, 800, 1600). It also covers accessory wiring (undervoltage release, shunt release, motor operator, alarm and auxiliary contacts), protection parameter adjustment, and routine inspection, testing, and maintenance procedures. This manual is written in Chinese.
Covers: Purpose and scope · Installation (busbar/cable selection, safety distances, tightening torque, altitude derating, temperature derating) · Outline and installation dimensions (front connection, rear connection, plug-in front/rear, draw-out) · Accessory installation and wiring (rotary handle, motor operator, undervoltage/shunt releases, alarm/auxiliary contacts) · Protection parameter setting and modification · Installation, use, maintenance, and repair
Latest HZK manuals
HZK HSM6E Series Electronic Molded Case Circuit Breaker User Manual
User Manual 22 pages · 1.7 MB · ZHUser manual for HZK HSM6E series electronic molded case circuit breakers covering installation, dimensions, protection settings, and maintenance.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in HZK manuals
What is the rated current range of the HSM6E series?
The HSM6E series covers rated currents from 32 A up to 1600 A.
From: HZK HSM6E Series Electronic Molded Case Circuit Breaker User Manual
Which standards does the HSM6E circuit breaker comply with?
It complies with IEC 60947-2 and GB/T 14048.2.
From: HZK HSM6E Series Electronic Molded Case Circuit Breaker User Manual