Jefa 150 KgM Direct Autopilot Drive Type I Installation Guide
This document provides installation instructions for the Jefa 150 KgM Direct Autopilot Drive Type I. It details electrical connections for 12-volt systems, including compatibility with various autopilot junction boxes like Simrad, B&G, and Raymarine. The guide specifies wire gauges for clutch and drive outputs and notes the need for specific clutch voltage settings for certain brands.
The guide also covers mechanical installation, including offset distances for different operating centers and special considerations for rack and pinion systems. It includes recommendations for reducing noise and vibrations using supplied rubber washers and bushes, as well as a step-by-step testing procedure to verify system operation before final commissioning.
Covers: Test data · Electrical Connections · Performance table · Compatibility · Mechanical installation · Rack and pinion system
Latest Jefa manuals
Jefa 150 KgM Direct Autopilot Drive Type I Installation Guide
Installation Guide 6 pages · 386 KB · ENInstallation guide for the Jefa 150 KgM Direct Autopilot Drive Type I, covering electrical connections, mechanical mounting, noise reduction, and testing…
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Jefa manuals
What is the average power consumption of the drive?
The average power consumption on 12 volts is 2 amps.
From: Jefa 150 KgM Direct Autopilot Drive Type I Installation Guide
What clutch voltage setting is required for B&G autopilots?
The clutch voltage should be adjusted to 12 volts, as the default is 9 volts.
From: Jefa 150 KgM Direct Autopilot Drive Type I Installation Guide