YR-E17 Wired Controller Operation and Installation Manual
The YR-E17 Wired Controller Operation & Installation Manual provides instructions for using the controller to adjust temperature, fan speed, timer settings, and other functions. It details the interface display parts, key functions such as energy saving and child lock, and explains how to configure the device using dip switches for various modes like fresh air units or master/slave configurations.
The document also includes specific wiring instructions for connecting the controller to indoor units. It describes three connection methods, including controlling up to 16 indoor units, and provides a table specifying wire gauge requirements based on communication wiring length to ensure proper signal transmission.
Covers: Parts and Functions · Key Operations · Dip Switch Interpretation · Timer Settings · Fan Speed Control · Wiring Connections

YR YR-E16b Wired Controller User Manual
The YR-E16b Wired Controller is designed for use with ductless split air conditioners. It features a main interface with keys for mode selection, fan speed adjustment, swing control, and temperature settings. The controller supports functions such as intelligent mode, turbo, child lock, forced defrost, ventilation, health airflow, sleep mode, and error code display. It can control multiple indoor units and allows users to set schedules with segmented or random timing.
Covers: Wired Controller Panel Functions · Features and Interface · Operation · Settings & Functions · Schedule Options · Installation
Latest YR manuals
YR-E17 Wired Controller Operation and Installation Manual
User Manual 50 pages · 558 KB · ENThis manual covers the operation, installation, and wiring instructions for the YR-E17 wired controller used with air conditioning systems.
YR YR-E16b Wired Controller User Manual
User Manual 11 pages · 1.5 MB · ENThis manual provides operation, settings, and installation instructions for the YR-E16b wired controller used with ductless split air conditioners.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in YR manuals
What is the temperature adjustment step in energy saving mode?
In energy saving mode and temp. compensation mode, the adjusting step is 1°C (1°F) a time.
From: YR-E17 Wired Controller Operation and Installation Manual
How many indoor units can one wired controller control?
One wired controller can control a maximum of 16 sets of indoor units.
From: YR-E17 Wired Controller Operation and Installation Manual
What is the default lowest temperature setting for cooling or dry mode?
The default lowest temp. of cooling/dry mode is 74°F.
What is the default highest temperature setting for heating mode?
The default highest temp. of heating mode is 78°F.