Featured Intra-Lock manuals

Intra-Lock AB1800-33ENFRITES INTRA-SPIN Operating Manual
This document is the operating manual for the Intra-Lock INTRA-SPIN centrifuge (Model AB1800-33ENFRITES). It provides instructions on intended use, safety notes, installation, and operation for separating autologous blood samples to prepare platelet-rich fibrin (PRF). The device is a medical product designed for the safe and rapid separation of substances with a density of no more than 1.2 kg/dm³.
Covers: How to use these operating instructions · Symbol meanings · Intended use · Remaining risks · Technical specifications · Notes on safety

Intra-Lock IntraSpin L-PRF Leukocyte- and Platelet-Rich Fibrin Instructions for Use
This document is the English Instructions for Use for the IntraSpin System from Intra-Lock International Inc., a centrifuge-based system intended for the safe and rapid preparation of autologous Leukocyte- and Platelet-Rich Fibrin (L-PRF) from a small sample of blood at the patient's point of care. The L-PRF is mixed with autograft and/or allograft bone prior to application to a bony defect for improving handling characteristics.
The manual covers indications and contraindications, safety notes for operating the centrifuge, the system components (centrifuge, blood collection tubes, collection sets, surgical instruments and the Xpression Box), compatible replacement parts, centrifuge setup, and cautions for handling blood collection tubes. Use is restricted by U.S. Federal law to a dentist or physician, and the device carries the CE mark under the Medical Devices Directive 93/42/EEC.
Covers: Indications for Use · Contraindications · Safety Notes · IntraSpin System Components · Compatible Parts · Brief Centrifuge Setup
Latest Intra-Lock manuals
Intra-Lock AB1800-33ENFRITES INTRA-SPIN Operating Manual
User Manual 447 pages · 29.3 MB · ENOperating manual for the Intra-Lock INTRA-SPIN centrifuge, designed for the separation of autologous blood samples to prepare platelet-rich fibrin.
Intra-Lock IntraSpin L-PRF Leukocyte- and Platelet-Rich Fibrin Instructions for Use
User Manual 472 pages · 12.1 MB · ENEnglish instructions for use for the Intra-Lock IntraSpin system for preparing autologous Leukocyte- and Platelet-Rich Fibrin (L-PRF) at the point of care.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Intra-Lock manuals
What is the intended use of the Intra-Spin Centrifuge?
It is intended for the safe and rapid separation of autologous blood samples for the preparation of autologous platelet rich fibrin (PRF).
From: Intra-Lock AB1800-33ENFRITES INTRA-SPIN Operating Manual
What is the maximum allowed density for the materials?
The centrifuge was designed only for the separation of substances or mixtures with a density of no more than 1.2 kg/dm³.
From: Intra-Lock AB1800-33ENFRITES INTRA-SPIN Operating Manual
What is the IntraSpin System used for?
It is intended for the safe and rapid preparation of autologous Leukocyte- and Platelet-Rich Fibrin (L-PRF) from a small sample of blood at the patient's point of care, which may be mixed with autograft and/or allograft bone before application to a bony defect.
From: Intra-Lock IntraSpin L-PRF Leukocyte- and Platelet-Rich Fibrin Instructions for Use
What speed and time should the IntraSpin centrifuge be set to?
Select speed 2700 and time 12:00 min, then press START; the cover opens automatically at the end of each cycle.
From: Intra-Lock IntraSpin L-PRF Leukocyte- and Platelet-Rich Fibrin Instructions for Use