Galvanic Applied Sciences GAS MICRO Electronic Volume Corrector Operator's Manual
The document serves as an operator's manual for the GAS MICRO Electronic Volume Corrector and Electronic Pressure Recorder. It covers features, unpacking, initial inspection, and detailed installation procedures including base setup, mounting on a meter, connecting pressure lines, and installing temperature RTDs.
The guide also details software installation and configuration through various screen tabs such as Primary Setup, Flow, Alarms, Modem, Logs, Display, and Modbus. It includes instructions for calibrating I/O and batteries, maintenance procedures for hardware components like the CPU and motherboard, and troubleshooting information.
Covers: Introducing the GAS MICRO Features · Unpacking and Initial Inspection · Installation (Base and Power Supply) · GAS MICRO Installation (Mounting and Connections) · LCD Display and Software Features · Software Configuration Screens

Galvanic Applied Sciences Model 902 H2S/Total Sulphur Analyzer Product Leaflet
The Galvanic Applied Sciences Model 902 H2S / Total Sulphur Analyzer measures hydrogen sulfide (H2S) in gaseous streams using the lead acetate tape method. It is designed for applications such as refineries, gas processing facilities, and pipeline custody transfer. The unit can also measure total sulphur when equipped with an optional furnace.
Covers: Lead Acetate Tape Method · Tape Transport System · Sample Chamber Assembly · Calibration Procedures · Total Sulphur Option · Permeable Membrane Dilution

Galvanic Applied Sciences AccuLase-GPA Tunable Diode Laser Adsorption Spectroscopy Analyzer Operation & Maintenance Manu
This manual provides instructions for the safe operation and maintenance of the AccuLase-GPA™ Tunable Diode Laser Adsorption Spectroscopy Analyzer. It is intended for use by trained personnel and covers system overview, component descriptions, user interface navigation, and web-based GUI usage. The document includes detailed safety guidelines and specifies that the analyzer can be configured for hazardous locations such as Class 1, Div. 2, Groups B, C, D (D2 Model) or Class 1, Div. 1, Groups B, C, D (D1 model).
The guide details maintenance and repair procedures, including extracting the component rail, removing the Herriott cell, cleaning mirrors, and maintaining the vacuum pump diaphragm and seals. It also provides troubleshooting information, diagnostic alarms, and a list of spare parts. The manual is Revision 5, dated April 2022.
Covers: Overview · Principle of Operation · Features of the Analyzer · System Operating Control · Installation and Safety · Components

Galvanic Applied Sciences ProTech903™ H2S and Total Sulfur Lead Acetate Tape Analyzer Operation Manual
This document provides detailed instructions for operating, installing, configuring, and maintaining the ProTech903™ H2S and Total Sulfur Lead Acetate Tape Analyzer. It covers setup procedures, software installation, sample analysis, calibration, maintenance, and troubleshooting. The analyzer is designed for use in hazardous environments and includes safety guidelines for operation and servicing. It supports both handheld keypad and graphical user interface (GUI) operation, with configurable parameters for streams, alarms, inputs, outputs, and sequencing.
Covers: Overview · Analyzer Components · Installation · Operating via Handheld Keypad · Graphical User Interface (GUI) · Operating the System
Latest Galvanic Applied Sciences manuals
Galvanic Applied Sciences GAS MICRO Electronic Volume Corrector Operator's Manual
User Manual 105 pages · 12.6 MB · ENThis manual provides installation, operation, and maintenance instructions for the Galvanic Applied Sciences GAS MICRO electronic volume corrector and…
Galvanic Applied Sciences Model 902 H2S/Total Sulphur Analyzer Product Leaflet
Product Leaflet 7 pages · 404 KB · ENThe Galvanic Applied Sciences Model 902 is a lead acetate tape analyzer for measuring H2S and total sulphur in gaseous streams, featuring up to eight stream…
Galvanic Applied Sciences AccuLase-GPA Tunable Diode Laser Adsorption Spectroscopy Analyzer Operation & Maintenance Manu
Service Manual 107 pages · 6.7 MB · ENComprehensive operation and maintenance manual for the AccuLase-GPA Tunable Diode Laser Adsorption Spectroscopy Analyzer, covering safety, installation, and…
Galvanic Applied Sciences ProTech903™ H2S and Total Sulfur Lead Acetate Tape Analyzer Operation Manual
User Manual 188 pages · 6 MB · ENUser manual for Galvanic Applied Sciences' ProTech903™ analyzer for measuring H2S and total sulfur using lead acetate tape.
Galvanic SulfurChrome Sulfur Analyzer Operation Manual
User Manual 132 pages · 3.4 MB · ENThis manual provides operation, installation, and maintenance instructions for the Galvanic Applied Sciences SulfurChrome sulfur chromatograph analyzer.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Service Manual
Disassembly, diagnostics and part numbers, for repair.
Questions answered in Galvanic Applied Sciences manuals
What is the part number of this manual?
The part number for this manual is MA1956.
From: Galvanic Applied Sciences GAS MICRO Electronic Volume Corrector Operator's Manual
What is the GAS MICRO Electronic Volume Corrector used for?
It serves as an electronic volume corrector and functions as an electronic pressure recorder.
From: Galvanic Applied Sciences GAS MICRO Electronic Volume Corrector Operator's Manual
What method does the analyzer use for detection?
The analyzer uses the lead acetate tape method, where H2S reacts with lead acetate to form a brown stain.
From: Galvanic Applied Sciences Model 902 H2S/Total Sulphur Analyzer Product Leaflet
Can the unit measure total sulphur?
Yes, it can measure total sulphur if equipped with an optional hydrogenation reaction furnace.
From: Galvanic Applied Sciences Model 902 H2S/Total Sulphur Analyzer Product Leaflet
What is the AccuLase-GPA™ designed for?
It is intended for use by trained personnel to safely operate and maintain the analyzer.
What safety classification can the AccuLase-GPA™ be configured for?
It can be configured for Class 1, Div. 2, Groups B, C, D (D2 Model) or Class 1, Div. 1, Groups B, C, D (D1 model).