Circassia NIOX VERO Respiratory Inflammation Monitor User Manual
The document is the Spanish user manual for the NIOX VERO respiratory inflammation monitor, published by Circassia AB in September 2019. It covers essential information for healthcare professionals, including device components, installation, user interface navigation, and step-by-step procedures for measuring fractional exhaled nitric oxide (FeNO) and environmental NO.
The manual details specific operational constraints and safety warnings, such as the maximum number of exhalations per hour to prevent internal condensation and the prohibition of using alcohol-based substances near the device. It also outlines the device's technical specifications, including dimensions, electrical characteristics, and battery autonomy, as well as procedures for connecting the device to a PC via USB or Bluetooth using the NIOX Panel software. This manual is written in Spanish.
Covers: Información importante · Descripción del producto · Instalación y configuración · Interfaz de usuario · Uso del NIOX VERO · Uso con NIOX Panel

Circassia NIOX VERO Respiratory Inflammation Monitor Instruction Manual
This document is the Spanish instruction manual for the Circassia NIOX VERO respiratory inflammation monitor. It describes intended use by trained healthcare professionals, components, setup, measurement, troubleshooting, preventive care, safety and technical characteristics.
The manual also covers use with NIOX Panel, alarm codes, component replacement, disposal and surveillance. Operating limits include ambient temperature from +10°C to +35°C and humidity from 20% to 80% RH. This manual is written in Spanish.
Covers: Important information · Product description · Installation and setup · User interface · Using NIOX VERO · Using with NIOX Panel
Latest Circassia manuals
Circassia NIOX VERO Respiratory Inflammation Monitor User Manual
User Manual 47 pages · 4.6 MB · ESThis manual provides instructions for the operation, maintenance, and safety precautions for the Circassia NIOX VERO respiratory inflammation monitor.
Circassia NIOX VERO Respiratory Inflammation Monitor Instruction Manual
User Manual 47 pages · 4.6 MB · ESSpanish instruction manual for the Circassia NIOX VERO respiratory inflammation monitor, covering use, safety, troubleshooting and specifications.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Circassia manuals
How many exhalations can be performed per hour?
Up to 10 exhalations per hour continuously, or 20 exhalations in an hour if the device is paused for at least 30 minutes.
From: Circassia NIOX VERO Respiratory Inflammation Monitor User Manual
Can alcohol be used to clean the device?
No, substances containing alcohol must not be used near or on the device as they can cause incorrect measurement results.
From: Circassia NIOX VERO Respiratory Inflammation Monitor User Manual
Who may use the NIOX VERO device?
It must be used exclusively by healthcare professionals with appropriate training.
From: Circassia NIOX VERO Respiratory Inflammation Monitor Instruction Manual
What is the NIOX VERO device?
It is a respiratory inflammation monitor.
From: Circassia NIOX VERO Respiratory Inflammation Monitor Instruction Manual