Featured Benchmark Scientific manuals

Benchmark Scientific E2100 Mini Power Supply Operating Manual
The Benchmark Scientific E2100 Mini Power Supply is an electrophoresis power supply designed for research use only. It provides 100 VDC or 200 VDC output and features two sets of output jacks to connect one or two gel tanks wired in parallel. The manual provides instructions for safe setup and operation, including connecting the power cord and electrophoresis gel box.
Covers: Introduction · Safety Warnings · Set up and Operation · Maintenance and Cleaning · Trouble Shooting · Specifications

Benchmark Scientific Digital Dry Bath II Users Manual
Benchmark Scientific's Digital Dry Bath II is a microprocessor-controlled heating unit designed to heat one, two, or four aluminum blocks or pans. It features high temperature uniformity and accuracy for applications involving microtubes, test tubes, and other small vessels.
The document provides instructions on setting the temperature using arrow buttons, utilizing the built-in digital timer function which alerts users without stopping heating, and performing user calibration to match certified reference thermometers.
Covers: SET UP and OPERATION · Setting the Temperature · Using and Setting the Timer · User Calibration Function · EER Code on the display
Latest Benchmark Scientific manuals
Benchmark Scientific E2100 Mini Power Supply Operating Manual
User Manual 8 pages · 168 KB · ENOperating manual for the Benchmark Scientific E2100 Mini Power Supply, covering setup, safety, maintenance, troubleshooting, and specifications for…
Benchmark Scientific Digital Dry Bath II Users Manual
User Manual 2 pages · 55 KB · ENThis manual covers the operation, setup, timer usage, calibration, and troubleshooting for Benchmark Scientific's BSH1001, BSH1002, and BSH1004 Digital Dry…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Benchmark Scientific manuals
What is the warranty period for the Mini Power Supply?
The Mini Power Supply is covered by a 2 year warranty against manufacturing defects.
From: Benchmark Scientific E2100 Mini Power Supply Operating Manual
What should be done if the indicator light is blinking?
The resistance of the load is too low, causing excess current. Adjust the concentration of buffer to maintain proper level of resistance.
From: Benchmark Scientific E2100 Mini Power Supply Operating Manual
What does the EER code on the display mean?
The EER code appears if the temperature sensor is shorted or senses an ambient temperature below 0C.
How long must a dry bath equilibrate at a calibration temperature?
The unit must be allowed to equilibrate for 45 minutes at the set calibration temperature.