Key facts
- Manuals
- 7
- Models
- 1
- Languages
- EN
- Last added
- 2026-10-17
AuCom models by category
Featured AuCom manuals

AuCom CSX Series Compact Soft Starter Product Familiarisation
The document provides an overview of the soft start market segmentation, identifying a gap between standard controllers and full-featured digital soft starters. It positions the CSX series as a new segment offering essential motor protection in a compact package.
Two styles are described: the CSX without motor protection and the CSXi with motor protection. The text details common specifications including power ranges from 7.5 to 110 kW at 400 VAC, voltage ranges of 200-440 VAC and 200-575 VAC, and approvals such as CE, UL508, CSA, and CCC.
Covers: Soft Start Market Segmentation · Market Opportunity · The CSX Series · CSX Styles and Models · Common Specifications · Equi-Vec Performance

AuCom MVE Soft Starter User Manual
This user manual provides detailed instructions for installing, operating, and maintaining the AuCom MVE soft starter. It covers features like soft start methods, motor protection mechanisms, and commissioning tools. The manual also includes safety warnings, troubleshooting steps, and maintenance schedules to ensure safe and reliable operation.
The MVE is designed for medium voltage motor control with robust protection features including thermal modeling, ground fault detection, and customizable trip settings. It supports remote control inputs and relay outputs, and includes diagnostic tools for performance monitoring and event logging.
Covers: About This Manual · Caution Statements · General Description · Installation · Operation · Motor Protection

AuCom EMX4i Soft Starter User Manual
This manual provides instructions for installing, configuring, and operating the AuCom EMX4i soft starter. It includes safety warnings, electrical shock risks, and precautions for unexpected operation. Sections cover setup procedures, control methods, protection levels, relay outputs, analog outputs, and troubleshooting. The manual also includes application examples and guidance for smart card integration with pump control and protection.
Covers: About This Manual · Disclaimer · Caution Statements · Electrical Shock Risk · Unexpected Operation · Installation

AuCom EMX4i Soft Starter User Manual
This document provides detailed instructions for installing, operating, and maintaining the AuCom EMX4i soft starter. It includes safety warnings, electrical precautions, setup procedures, and troubleshooting guidance. The manual emphasizes the importance of disconnecting power before servicing and outlines protection features and coordination with short-circuit devices. It also covers programming, communication, and various control methods for motor operation.
The manual is structured to guide users through system design, parameter programming, and fault handling, with sections on safety, installation, commissioning, and advanced applications such as pump control and protection.
Covers: About This Manual · Caution Statements · System Design · Model Selection · Power Terminations · Setup Tools
Latest AuCom manuals
AuCom CSX Series Compact Soft Starter Product Familiarisation
Product Leaflet 54 pages · 5.2 MB · ENThis document introduces the AuCom CSX series compact soft starters, explaining their market position and features.
AuCom MVE Soft Starter User Manual
User Manual 77 pages · 6.4 MB · ENUser manual for AuCom's MVE soft starter, covering installation, operation, protection features, and troubleshooting for medium voltage motor control.
AuCom EMX4i Soft Starter User Manual
User Manual 126 pages · 1.7 MB · ENUser manual for the AuCom EMX4i soft starter, covering installation, operation, protection, and troubleshooting.
AuCom EMX4i Soft Starter User Manual
User Manual 116 pages · 1.7 MB · ENUser manual for the AuCom EMX4i soft starter, covering installation, operation, safety, and troubleshooting.
AuCom EMX4e Soft Starter User Manual
User Manual 98 pages · 1.5 MB · ENUser manual for the AuCom EMX4e soft starter, covering installation, operation, safety, and troubleshooting.
AuCom CSXi Soft Starter User Manual
User Manual 20 pages · 445 KB · ENThis manual provides installation, operation, and maintenance instructions for the AuCom CSXi soft starter series.
AuCom CSX Soft Starter User Manual
User Manual 16 pages · 545 KB · ENThis manual provides installation, operation, and maintenance instructions for the AuCom CSX soft starter series.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in AuCom manuals
Does the CSX require an additional line contactor?
No, use of a two phase soft starter does not require an additional line contactor as compared with a three phase soft starter.
From: AuCom CSX Series Compact Soft Starter Product Familiarisation
Can the CSX provide electrical isolation between supply and motor?
No, nor can any form of electronic switching device including three phase soft starters or frequency converters.
From: AuCom CSX Series Compact Soft Starter Product Familiarisation
What software versions is this manual compatible with?
This manual is compatible with MVE soft starters using version 1.33 control software and version 2.36 interface software.
What protection features does the MVE offer?
The MVE offers protection against undervoltage, overvoltage, phase loss, phase sequence, shorted SCR, motor overload, instantaneous overcurrent, time-overcurrent, ground fault, undercurrent, current imbalance, motor thermistor, excess start time, power circuit loss, input trip, and internal/external communications failure.
Is the EMX4i user serviceable?
No, the EMX4i is not user serviceable. It should only be serviced by authorized service personnel.
What safety precautions should be taken when accessing the EMX4i?
Always disconnect the soft starter from mains voltage before accessing the starter or load. The STOP function does not isolate dangerous voltages.