Featured Teledyne Hastings Instruments manuals

Teledyne Hastings Instruments PB-181-02/08 Application Note: Improve Fed-Batch Fermentation by Measuring Mass Flow
The document discusses the importance of precise gas flow measurement in fed-batch fermentation processes. It highlights that passive methods like needle valves are susceptible to errors due to temperature or pressure fluctuations, whereas mass flow technology provides accurate measurements independent of these conditions. The note outlines objectives such as ensuring accurate air, oxygen, and CO2 flow and providing signals for documentation or closed-loop control.
Covers: Improve Fed-Batch Fermentation · Measuring Mass Flow · Passive Flow Methods · Mass Flow Meters vs Controllers · Closed-Loop Control · Instrument Selection

Teledyne Hastings Instruments Digital AVC (DAVC-4, DAVC-5, DAVC-6) User Manual
This user manual provides detailed instructions for installing, operating, and calibrating the Digital AVC vacuum gauges (DAVC-4, DAVC-5, DAVC-6). It covers power requirements, serial and analog output configurations, alarm settings, and calibration procedures using reference tubes. The manual also includes safety information, compliance data, and accessory details for compatible gauge tubes and extension cables.
The Digital AVC is a digital readout version of THI’s AVC vacuum gauge, using heated noble-metal thermocouple tubes for pressure measurement. It supports three tube families (DV-4, DV-5, DV-6) with different pressure ranges and provides both digital and analog outputs for integration with control systems.
Covers: General Information · Safety · Compliance Data · Specifications · Thermal Coefficient · Accessories
Latest Teledyne Hastings Instruments manuals
Teledyne Hastings Instruments PB-181-02/08 Application Note: Improve Fed-Batch Fermentation by Measuring Mass Flow
Application Note 2 pages · 107 KB · ENThis application note explains how to improve fed-batch fermentation consistency by measuring and controlling gas flows using Teledyne Hastings mass flow…
Teledyne Hastings Instruments Digital AVC (DAVC-4, DAVC-5, DAVC-6) User Manual
User Manual 23 pages · 785 KB · ENUser manual for Teledyne Hastings Instruments' Digital AVC vacuum gauges, covering installation, operation, calibration, and specifications for DAVC-4…
Which document do I need?
Application Note
How to use the product for one specific task, with worked examples.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Teledyne Hastings Instruments manuals
Why are passive flow devices susceptible to errors?
They are highly susceptible to errors due to temperature or pressure fluctuations which often occur due to local environmental and supply pressure conditions.
What is the advantage of mass flow meters over volumetric flow?
Mass flow meters produce accurate flow measurement and are independent of pressure and temperature conditions.
What are the pressure ranges for the DAVC-4, DAVC-5, and DAVC-6 models?
DAVC-4: 0.2 - 20 Torr; DAVC-5: 0.1 – 100 mTorr; DAVC-6: 1.0 - 1000 mTorr.
From: Teledyne Hastings Instruments Digital AVC (DAVC-4, DAVC-5, DAVC-6) User Manual
What is the power requirement for the DAVC?
The DAVC requires 11–32 VDC, with a minimum power draw of 0.7 Watts.
From: Teledyne Hastings Instruments Digital AVC (DAVC-4, DAVC-5, DAVC-6) User Manual